vc t60b table type pulse vacuum steam sterilizer
MoreVET

Table Type Pulse Vacuum Steam Sterilizer

VC-T60B Table Type Pulse Vacuum Steam Sterilizer

SKU
VC-T60B
Brand
MoreVET
Manufactured by
MoreVET
Availability
In stock
  • Worldwide shipping
Regulatory: For professional veterinary use only. Certification and regulatory status vary by product and country; confirm local regulatory requirements before purchase or use.

Clinical overview

Built for surgical precision

Features

-The LCD touch screen can display the temperature, pressure, time, running state, fault alarm and equipment running curve and other information in real time, which makes the sterilization information more intuitive and convenient for users to observe the running state of the equipment

-Preheating, replacement, heating, sterilization, steam exhaust, vacuum drying process automatic operation; it is steam as the medium, using efficient vacuum system, repeated vacuum, to achieve the effect of sterilization and drying

-Heating, sterilizing, exhausting and drying totally automatic.

-Chamber is heated by film heater, saving energy and time.

-0.22um high efficiency air filter,to avoid re-contamination of sterilized materials with filtration efficiency over 99.5%.

-Water filter in tank and chamber are quick to disassemble and easy for cleaning.

-Built-in stainless steel water tank, inner cycle of steam and water.

-Standard built-in printer.

-Standard USB port.

 

Technical Specifications

PARAMETER

SPECIFICATION

Main Body

Volume

60 L

Material

06Cr19Ni10 stainless steel

Design pressure

-0.1 / 0.3 Mpa

Design temperature

150℃

Sterilization temperature selection range

105℃ -134℃

Rated working temperature

121℃ / 134℃

Service life

8 years

Main body insulation

10mm glass wool

Lumen wall heating

Film-coated cavity wall heating film

Seal Door

Door panel

Stretch door panel, material thickness of 2.5mm

Material

06Cr19Ni10 stainless steel

Open and close the door mode

Automatic quick door opening

Safety interlock

If the door of pressure safety interlock, the power can be connected to heat and generate steam; there is pressure in the inner chamber and the door cannot be open.

Door sealing method

Self-expansion sealing ring, using transparent medical silicone rubber molding

Door cover

Cold plate spray plastic shell, effectively prevent scald

Pipe System

Control valves

5 direct-action solenoid valves, and 3 manual ball valves

Steam generation mode

Built-in energy storage steam generator, steam generator, steam generation speed is fast, high quality

Water injection and drainage method

Automatic water injection, automatic drainage

Water storage device

Built-in open water tank, steam water internal circulation, water tank capacity of 14L

Pressure gauge

Range: -0.1~0.5MPa

Precision level: level 1.6

Removable filter

Manual removable filter, easy to clean, more humanized

Navar

Control mode

SCM control

Interface display

The LCD touch screen can display the temperature, pressure, time, running state, fault alarm and equipment running curve and other information in real time, which makes the sterilization information more intuitive and convenient for users to observe the running state of the equipment

Process control

Preheating, replacement, heating, sterilization, steam exhaust, vacuum drying process automatic operation; it is steam as the medium, using efficient vacuum system, repeated vacuum, to achieve the effect of sterilization and drying

Multi-point temperature control technology

Non-airtight liquid program uses mobile temperature sensor to measure the temperature, which can detect the internal temperature of the liquid, the liquid internal temperature is more intuitive and clear

Thermal insulation function

The insulation function can be set according to the need to realize liquid culture medium sterilization, medium dissolution-insulation function

Safety protection

With over temperature automatic protection device, anti-dry burning protection device, over pressure automatic discharge device, over-current protection device, electronic circuit safety device

Self-calibration function

It has a complete background self-calibration system to realize the calibration of pressure, temperature and other system parameters. Without splitting the instrument, the permission tool can be used for on-site adjustment

Independent installation of pressure sensor

An independent pressure transmitter is installed in the inner chamber and the evaporator to ensure that the equipment pressure is within the safety control range

Software

Program name

Bare procedures, encapsulation procedures, rubber procedures, dressing procedures, liquid procedures, liquid customization, solid customization, medium sterilization, medium dissolution and other procedures, as well as B & D testing and vacuum testing procedures

Scope of application

Non-liquid procedures are suitable for sterilization of surgical instruments, solid bare instruments, packaging instruments, rubber loads, etc., and liquid procedures are suitable for sterilization of water, culture media and other liquids

Overall parameters

Overall parameters

One 304 pallet frame and three pallets

Equipment power supply

Single-phase: AC220V, 50Hz

Equipment power

6.2kW

Chamber dimension (mm) (Φ×L)

Φ 391 x 521

Overall dimension (mm) (L×W×H)

990 x 804 x 675

Packaging size (mm) (L×W×H)

1130 x 870 x 830

Net weight (kg)

181

Gross weight (kg)

220

 

Technical specifications

Engineering at a glance

Documentation, IFU and DOCs available on request — contact our sales team for the full regulatory file.

Volume
60 L
Material
06Cr19Ni10 stainless steel
Design pressure
-0.1 / 0.3 Mpa
Design temperature
150℃
Sterilization temperature selection range
105℃ -134℃
Rated working temperature
121℃ / 134℃
Service life
8 years
Main body insulation
10mm glass wool
Lumen wall heating
Film-coated cavity wall heating film
Door panel
Stretch door panel, material thickness of 2.5mm
Material
06Cr19Ni10 stainless steel
Open and close the door mode
Automatic quick door opening
Safety interlock
If the door of pressure safety interlock, the power can be connected to heat and generate steam; there is pressure in the inner chamber and the door cannot be open.
Door sealing method
Self-expansion sealing ring, using transparent medical silicone rubber molding
Door cover
Cold plate spray plastic shell, effectively prevent scald
Control valves
5 direct-action solenoid valves, and 3 manual ball valves
Steam generation mode
Built-in energy storage steam generator, steam generator, steam generation speed is fast, high quality
Water injection and drainage method
Automatic water injection, automatic drainage
Water storage device
Built-in open water tank, steam water internal circulation, water tank capacity of 14L
Pressure gauge
Range: -0.1~0.5MPa Precision level: level 1.6
Removable filter
Manual removable filter, easy to clean, more humanized
Control mode
SCM control
Interface display
The LCD touch screen can display the temperature, pressure, time, running state, fault alarm and equipment running curve and other information in real time, which makes the sterilization information more intuitive and convenient for users to observe the running state of the equipment
Process control
Preheating, replacement, heating, sterilization, steam exhaust, vacuum drying process automatic operation; it is steam as the medium, using efficient vacuum system, repeated vacuum, to achieve the effect of sterilization and drying
Multi-point temperature control technology
Non-airtight liquid program uses mobile temperature sensor to measure the temperature, which can detect the internal temperature of the liquid, the liquid internal temperature is more intuitive and clear
Thermal insulation function
The insulation function can be set according to the need to realize liquid culture medium sterilization, medium dissolution-insulation function
Safety protection
With over temperature automatic protection device, anti-dry burning protection device, over pressure automatic discharge device, over-current protection device, electronic circuit safety device
Self-calibration function
It has a complete background self-calibration system to realize the calibration of pressure, temperature and other system parameters. Without splitting the instrument, the permission tool can be used for on-site adjustment
Independent installation of pressure sensor
An independent pressure transmitter is installed in the inner chamber and the evaporator to ensure that the equipment pressure is within the safety control range
Program name
Bare procedures, encapsulation procedures, rubber procedures, dressing procedures, liquid procedures, liquid customization, solid customization, medium sterilization, medium dissolution and other procedures, as well as B & D testing and vacuum testing procedures
Scope of application
Non-liquid procedures are suitable for sterilization of surgical instruments, solid bare instruments, packaging instruments, rubber loads, etc., and liquid procedures are suitable for sterilization of water, culture media and other liquids
Overall parameters
One 304 pallet frame and three pallets
Equipment power supply
Single-phase: AC220V, 50Hz
Equipment power
6.2kW
Chamber dimension (mm) (Φ×L)
Φ 391 x 521
Overall dimension (mm) (L×W×H)
990 x 804 x 675
Packaging size (mm) (L×W×H)
1130 x 870 x 830
Net weight (kg)
181
Gross weight (kg)
220

Documents & downloads

Regulatory paperwork & manuals

Pre-cleared documentation for this device. Full tender-pack originals are available on request.

Documents & downloads

Regulatory paperwork & manuals

This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.

Get in touch

Need configuration help, certificates, or volume pricing?

Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.