The halogen field gives a warm, even light across the surgical site with minimal shadowing when I lean in for orthopaedic work. It does throw a fair bit of heat over long procedures.
Dr. Andrew Coleman, DVM, DACVSVerified buyerOct 29, 2025

VML12L Halogen Operating Lamp
Clinical overview
Introduction
AML1205L, AML12L, AML09L use of multiple different sources, by focusing knob, so the beam is irradiated from different locations surgery, reduce the shadow medical staff head, hands and other parts caused. The illumination can be adjusted according to actual needs
Technical Specifications
|
PARAMETER |
SPECIFICATION |
|
Major Bulb Illumination |
≥120,000LX (at 1m distance) |
|
Color Temperature |
4000K±500K |
|
Color Rendering Index |
100≥Ra≥85 |
|
Depth of Light Beam |
≥500mm |
|
The Value of the Total Irradiance (service range for temperature rise≤10℃) |
≤6mW/m²lx |
|
Total Irradiance (temperature rise on the head of patient under surgical operation≤2℃) |
≤600W/m² |
|
Mains Voltage |
AC110V/220V±10%, 50/60Hz |
|
Bulb Voltage |
AC24V Bulb Power |
|
Bulb Power |
300W |
|
Input Power |
350VA |
|
Height for Installation |
280-320cm |
|
Note: If you want use halogen bulbs, please mention before your order. |
|
Technical specifications
Documentation, IFU and DOCs available on request — contact our sales team for the full regulatory file.
Documents & downloads
Pre-cleared documentation for this device. Full tender-pack originals are available on request.
Documents & downloads
This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.
Get in touch
Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.
The halogen field gives a warm, even light across the surgical site with minimal shadowing when I lean in for orthopaedic work. It does throw a fair bit of heat over long procedures.
Dr. Andrew Coleman, DVM, DACVSVerified buyerOct 29, 2025
Illumination is perfectly adequate for routine spays and dentals, but the bulb heat is noticeable during extended anaesthesia. I would have liked a cooler spectrum for prolonged theatre use.
Dr. Martin Ellis, VMDVerified buyerMar 11, 2025
Colour rendering is true enough that tissue planes read accurately during soft-tissue dissection. The arm holds position without drift once you set it.
Dr. Clara Nguyen, DVMJun 4, 2024

VML1205L Halogen Operating Lamp

VML09L Halogen Operating Lamp

VML05L.III Halogen Operating Lamp

VML05L.I Halogen Operating Lamp

VML05L Halogen Operating Lamp

VML04L.III Halogen Operating Lamp

VML04L.I Halogen Operating Lamp