Vet Multiparameter Monitor
VET-2000V Vet Multiparameter Monitor
- SKU
- VET-2000V
- Brand
- MoreVET
- Manufactured by
- MoreVET
- Availability
- In stock
- ✓ Worldwide shipping
Clinical overview
Built for surgical precision
Product Features
- 7″ high-resolution color LCD display with adjustable brightness
- Lightweight and portable, easy for veterinarians to carry out
- Built-in rechargeable lithium battery for long-term continuous operation
- Selectable 3-lead and 5-lead ECG cables
- Variety of NIBP cuffs for different-sized animals
- Expanded heart rate values and veterinary-specific SpO2 sensors for multiple species
- Widely used in pet hospitals and animal clinics
- Special NIBP technology designed for animals ensures safety and accuracy
Technical Specifications
|
PARAMETER |
SPECIFICATION |
|
|
DISPLAY |
||
|
Screen size |
177.8 mm (7 in.), measured diagonally |
|
|
Screen type |
TFT LCD, white LED backlight, viewing cone of 60° and optimal viewing distance of 1.5 meter |
|
|
Resolution |
800 x 480 pixels |
|
|
ECG |
||
|
Measurement range |
25bpm to 350bpm |
|
|
Lead selection |
I,II, III,V, aVF,aVL,aVR |
|
|
Display gain |
X1/4, X1/2, X1, X2, X4 |
|
|
Didplay sweep speed |
6.25mm/s,12.5mm/s,25mm/s,50mm/s |
|
|
Accuracy |
±2BPM or ±2% (whichever is greater) |
|
|
Resolution |
1BPM |
|
|
NIBP |
|
|
|
Method |
Oscillometric |
|
|
Measurement range |
0-300mmHg |
|
|
Accuracy |
Based on ANSI/AAMI SP10:1992 and 2002 Standards |
|
|
Measurement time |
30 to 50s typical , 180s maximum |
|
|
AUTO interval times |
2, 3, 5, 10, 30 min, or 1, 2 h |
|
|
TEMPERATURE |
||
|
Measuring range |
0-50° |
|
|
Accuracy |
±0.2°C |
|
|
Resolution |
0.1°C |
|
|
SPO2 |
||
|
Range |
1%-100% |
|
|
Accuracy |
70-100% (±2% ),<70% undefined |
|
|
Resolution |
1% |
|
|
Display sweep speed |
10.00 mm/sec |
|
|
PULSE RATE |
||
|
Measurement range |
25bpm to 350bpm |
|
|
Accuracy |
±2 bpm / ±2% (take maximum) |
|
|
Resolution |
1bpm |
|
|
RESPIRATION |
||
|
Measurement range |
0-130rpm |
|
|
Accuracy |
±1rpm |
|
|
Resolution |
1rpm |
|
|
SIDESTREAM ETCO2 (OPTIONAL) |
||
|
Range |
0-150mmHg |
|
|
Accuracy |
0-40mmHg (±2mmHg); 41-150mmHg (±10% of reading) |
|
|
Resolution |
0.1mmHg |
|
|
Flow rate |
50 ml/min ±10 ml/min |
|
|
ELECTRICAL |
||
|
Battery |
Four new lithium batteries with 4,400mAh will typically provide 4.5 hours of monitoring with no external communication, no audible alarm sound, and at an ambient temperature of 25°C |
|
|
Type |
Lithium Batteries, 4,400mAh, DC 11.1V |
|
|
Voltage |
AC 100-240V, 50-60Hz, 80VA |
|
|
ENVIRONMENTAL |
||
|
Temperature |
Transport and storage |
-40°C to 75°C (-40°F to 167°F) |
|
Humidity |
Operating conditions |
0°C to 50°C (32°F to 122°F) |
|
Altitude |
-500 to 5,000 m (-1,640 to 16,404 ft.) |
|
|
Relative humidity |
15% to 95% noncondensing |
|
|
TREND |
||
|
Memory |
Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements |
|
|
Tabular format |
One table for all parameters |
|
|
ALARMS |
||
|
Categories |
Patient status and system status |
|
|
Priorities |
Low, medium, and high |
|
|
Notification |
Audible and visual |
|
|
Setting |
Full storage, low battery and sensor off |
|
|
Alarm volume level |
45 to 85 decibels |
|
|
Alarm system delay |
< 10 seconds |
|
|
DIMENSION AND WEIGHT |
||
|
Weight |
2.05kg (4.52 lb), including 1 battery |
|
|
Dimensions |
324mmW *129mmH*183mmD (12.76in.W x 5.08in.H x 7.20in.D) |
|
|
CONFIGURATION |
||
|
Standard |
SpO2 + ECG + NIBP + RESP + TEMP |
|
|
Optional |
1. SpO2; 2. SpO2 + NIBP; 3. SpO2 + NIBP + ECG; SpO2 + NIBP + TEMP; 4. SpO2 + ECG + NIBP + RESP + TEMP + ETCO2 etc.; 5. Lithium Battery 6. Trolley 7. Brace 8. IPMS8600 Central monitoring system |
|
Technical specifications
Engineering at a glance
Documentation, IFU and DOCs available on request — contact our sales team for the full regulatory file.
- Screen size
- 177.8 mm (7 in.), measured diagonally
- Screen type
- TFT LCD, white LED backlight, viewing cone of 60° and optimal viewing distance of 1.5 meter
- Resolution
- 800 x 480 pixels
- Measurement range
- 25bpm to 350bpm
- Lead selection
- I,II, III,V, aVF,aVL,aVR
- Display gain
- X1/4, X1/2, X1, X2, X4
- Didplay sweep speed
- 6.25mm/s,12.5mm/s,25mm/s,50mm/s
- Accuracy
- ±2BPM or ±2% (whichever is greater)
- Resolution
- 1BPM
- Method
- Oscillometric
- Measurement range
- 0-300mmHg
- Accuracy
- Based on ANSI/AAMI SP10:1992 and 2002 Standards
- Measurement time
- 30 to 50s typical , 180s maximum
- AUTO interval times
- 2, 3, 5, 10, 30 min, or 1, 2 h
- Measuring range
- 0-50°
- Accuracy
- ±0.2°C
- Resolution
- 0.1°C
- Range
- 1%-100%
- Accuracy
- 70-100% (±2% ),<70% undefined
- Resolution
- 1%
- Display sweep speed
- 10.00 mm/sec
- Measurement range
- 25bpm to 350bpm
- Accuracy
- ±2 bpm / ±2% (take maximum)
- Resolution
- 1bpm
- Measurement range
- 0-130rpm
- Accuracy
- ±1rpm
- Resolution
- 1rpm
- Range
- 0-150mmHg
- Accuracy
- 0-40mmHg (±2mmHg); 41-150mmHg (±10% of reading)
- Resolution
- 0.1mmHg
- Flow rate
- 50 ml/min ±10 ml/min
- Battery
- Four new lithium batteries with 4,400mAh will typically provide 4.5 hours of monitoring with no external communication, no audible alarm sound, and at an ambient temperature of 25°C
- Type
- Lithium Batteries, 4,400mAh, DC 11.1V
- Voltage
- AC 100-240V, 50-60Hz, 80VA
- Temperature
- Transport and storage -40°C to 75°C (-40°F to 167°F)
- Humidity
- Operating conditions 0°C to 50°C (32°F to 122°F)
- Altitude
- -500 to 5,000 m (-1,640 to 16,404 ft.)
- Relative humidity
- 15% to 95% noncondensing
- Memory
- Saves a total of 120 hours of data events; saves date and time, alarm conditions, measurements
- Tabular format
- One table for all parameters
- Categories
- Patient status and system status
- Priorities
- Low, medium, and high
- Notification
- Audible and visual
- Setting
- Full storage, low battery and sensor off
- Alarm volume level
- 45 to 85 decibels
- Alarm system delay
- < 10 seconds
- Weight
- 2.05kg (4.52 lb), including 1 battery
- Dimensions
- 324mmW *129mmH*183mmD (12.76in.W x 5.08in.H x 7.20in.D)
- Standard
- SpO2 + ECG + NIBP + RESP + TEMP
- Optional
- 1. SpO2; 2. SpO2 + NIBP; 3. SpO2 + NIBP + ECG; SpO2 + NIBP + TEMP; 4. SpO2 + ECG + NIBP + RESP + TEMP + ETCO2 etc.; 5. Lithium Battery 6. Trolley 7. Brace 8. IPMS8600 Central monitoring system
Documents & downloads
Regulatory paperwork & manuals
Pre-cleared documentation for this device. Full tender-pack originals are available on request.
Documents & downloads
Regulatory paperwork & manuals
This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.
Get in touch
Need configuration help, certificates, or volume pricing?
Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.
Related products
See all →
VET Multiparameter Monitor
VET-E12 VET Multiparameter Monitor

Vet Multiparameter Monitor
VET-5000V Vet Multiparameter Monitor

VET Multiparameter Monitor
VET-M12 VET Multiparameter Monitor

Mini Veterinary Monitor
VET-M3T Mini Veterinary Monitor