
VET Multiparameter Monitor
VET-M12 VET Multiparameter Monitor
- SKU
- VET-M12
- Brand
- MoreVET
- Manufactured by
- MoreVET
- Availability
- In stock
- ā Worldwide shipping
Clinical overview
Built for surgical precision
Features
- 12-inch high-brightness LCD monitor.
- Mirror display, new visual effect, more intimate protection monitor
- Multiple working modes: diagnostic, monitoring, surgical mode.
- Suitable for different groups of pets: large, medium, small pets.
- Multiple display modes: standard, large character, trend graph, blood pressure list, etc
- Support multi-lead display of ECG waveforms on the same screen.
- Equipped with a blood pressure cuff for pets Accurate blood pressure measurement.
- Multiple analysis functions.
- Quick setup alarm f
- Built-in high-capacity lithium battery, long standby time.
- Suitable for use in a variety of conditions such as operating rooms.
Ā
Technical Specifications
|
PARAMETER |
SPECIFICATION |
|
|
ECG |
||
|
Lead mode |
3/5-lead ECG input |
|
|
Lead selection |
I, I, lI, aVR, aVL, aVF, V |
|
|
Gain |
AUTO, 2.5 mm/mV (x0.25), 5mm/mV (x0.5),10 mm/mV (x1), 20 mm/mV (x2)Ā |
|
|
Support functions |
Support ST, QT and ARR functions |
|
|
Bandwidth (-3dB) |
Diagnostic mode: 0.05-150Hz |
|
|
Monitor mode |
0.5- 40Hz |
|
|
Operation mode |
1~25Hz |
|
|
ST mode |
0.05~40Hz |
|
|
Signal quality display |
Expression way: numerical displayĀ and waveform color |
|
|
HR measurement range |
10~400 bpm |
|
|
HR resolution |
1 bpm |
|
|
HR accuracy |
+1% or +1 bpm, whichever is greater |
|
|
NIBP |
||
|
Measurement parameters |
SYS, DIA, MAP |
|
|
Mode of operation |
Manual, Sequence, Auto |
|
|
Unit |
mmHg/KPa |
|
|
Measuring range of cuff pressure |
0~300mmHg |
|
|
Measurement range: |
Big Animal |
SYS:40~270mmHg |
|
DIA:10~215mmHg |
||
|
MEAN:20~235mmHg |
||
|
Medium Animal Ā Ā Ā |
SYS:40~200mmHg |
|
|
DIA:10~150mmHg |
||
|
MEAN:20~160mmHg |
||
|
Small Animal |
SYS:40~135mmHg |
|
|
DIA:10~100mmHg |
||
|
MEAN:20~110mmHg |
||
|
Static pressure accuracy |
±3mmHg |
|
|
Dynamic Pressure Measurement Error of Simulator |
±5mmHg |
|
|
Pressure resolution |
1 mmHg or 0.1kPa |
|
|
SpO2 |
||
|
Measuring range |
0~100% |
|
|
Sensitivity |
High, Medium, Low |
|
|
Accuracy |
At 70~100%,+2% |
|
|
At 0~69, unspecified |
||
|
Alarm range |
0~100% |
|
|
PR measurement range |
20 bpm~300 bpm |
|
|
PR resolution |
1 bpm |
|
|
PR accuracy |
±1bpm (non-motion conditions) |
|
|
PR alarm range |
0~250 bpm |
|
|
RESP. |
||
|
Measurement parameter |
Respiration rate and respiration waveform |
|
|
Measurement method |
Thoracic Electrical Bioimpedance |
|
|
Measurement range |
Big animal: 0~120 rpm |
|
|
MediumĀ animal: 0~150 rpm |
||
|
Small animal: 0~150 rpm |
||
|
Resolution |
1 rpm |
|
|
Accuracy |
+2 rpm or +2% ļ¼whichever is greater. |
|
|
TEMPERATURE |
||
|
Temp parameter |
T1,T2,TD |
|
|
Measurement site |
Surface and coelom |
|
|
Measuring range |
0°C~50°C (32F~122*F) |
|
|
Resolution |
0.1°C or 0.1° F |
|
|
IBPĀ (OPTIONAL) |
||
|
Measuring range |
-50~300 mmHg |
|
|
Resolution |
1 mmHg |
|
|
Accuracy |
±2mmHg or 2% of the reading,whichever is greater (exclusive of transducer) ±4mmHg or 4% of the reading,whichever is greater (inclusion of transducer) |
|
|
Dynamic |
±4mmHg or 4% of the reading,whichever is greater |
|
|
Unit |
mmHg , KPa |
|
|
Sensitivity of transducer |
5uVN/mmHg, 2% |
|
|
Transducer sites |
ART/PA/CVP/L AP/RAP/ICP |
|
|
CO2Ā (OPTONAL) |
||
|
Measurement parameter |
EtCO2, FiCO2, a CO2 waveform and awRR |
|
|
Measurement method |
Mainstream, sidestream |
|
|
Unit |
mmHg, kPa and % |
|
|
EtCO2/FiCO2 measuringĀ range |
0% ~ 19.7% (0mmHg ~ 150mmHg) |
|
|
BATTERY |
||
|
Type |
Rechargeable lithium battery,2000mAh |
|
|
Operating time |
Operating time under the normal use and full chargeā„240 mins |
|
|
SIZE & WEIGHT |
||
|
Product size |
305*162*290mm |
|
|
Net Weight |
4KG |
|
Ā
Standard Configuration
- 3/5-lead ECG, HR, RESP, NIBP, SpO2, PR, TEMP
- Rechargeable lithium battery
Ā
Optional Configuration
- 2-TEMP Probe,2-IBP,Suntech NIBP,Nellcor SpO2, Sidestreamor MainstreamĀ EtCO2
- Thermal Recorder
- Central Working Station
- Trolley or Wall Bracket
Technical specifications
Engineering at a glance
Documentation, IFU and DOCs available on request ā contact our sales team for the full regulatory file.
- Lead mode
- 3/5-lead ECG input
- Lead selection
- I, I, lI, aVR, aVL, aVF, V
- Gain
- AUTO, 2.5 mm/mV (x0.25), 5mm/mV (x0.5),10 mm/mV (x1), 20 mm/mV (x2)
- Support functions
- Support ST, QT and ARR functions
- Bandwidth (-3dB)
- Diagnostic mode: 0.05-150Hz
- Monitor mode
- 0.5- 40Hz
- Operation mode
- 1~25Hz
- ST mode
- 0.05~40Hz
- Signal quality display
- Expression way: numerical displayĀ and waveform color
- HR measurement range
- 10~400 bpm
- HR resolution
- 1 bpm
- HR accuracy
- +1% or +1 bpm, whichever is greater
- Measurement parameters
- SYS, DIA, MAP
- Mode of operation
- Manual, Sequence, Auto
- Unit
- mmHg/KPa
- Measuring range of cuff pressure
- 0~300mmHg
- Measurement range:
- Big Animal SYS:40~270mmHg
- Medium Animal
- SYS:40~200mmHg
- Small Animal
- SYS:40~135mmHg
- Static pressure accuracy
- ±3mmHg
- Dynamic Pressure Measurement Error of Simulator
- ±5mmHg
- Pressure resolution
- 1 mmHg or 0.1kPa
- Measuring range
- 0~100%
- Sensitivity
- High, Medium, Low
- Accuracy
- At 70~100%,+2%
- Alarm range
- 0~100%
- PR measurement range
- 20 bpm~300 bpm
- PR resolution
- 1 bpm
- PR accuracy
- ±1bpm (non-motion conditions)
- PR alarm range
- 0~250 bpm
- Measurement parameter
- Respiration rate and respiration waveform
- Measurement method
- Thoracic Electrical Bioimpedance
- Measurement range
- Big animal: 0~120 rpm
- Resolution
- 1 rpm
- Accuracy
- +2 rpm or +2% ļ¼whichever is greater.
- Temp parameter
- T1,T2,TD
- Measurement site
- Surface and coelom
- Measuring range
- 0°C~50°C (32F~122*F)
- Resolution
- 0.1°C or 0.1° F
- Measuring range
- -50~300 mmHg
- Resolution
- 1 mmHg
- Accuracy
- ±2mmHg or 2% of the reading,whichever is greater (exclusive of transducer) ±4mmHg or 4% of the reading,whichever is greater (inclusion of transducer)
- Dynamic
- ±4mmHg or 4% of the reading,whichever is greater
- Unit
- mmHg , KPa
- Sensitivity of transducer
- 5uVN/mmHg, 2%
- Transducer sites
- ART/PA/CVP/L AP/RAP/ICP
- Measurement parameter
- EtCO2, FiCO2, a CO2 waveform and awRR
- Measurement method
- Mainstream, sidestream
- Unit
- mmHg, kPa and %
- EtCO2/FiCO2 measuringĀ range
- 0% ~ 19.7% (0mmHg ~ 150mmHg)
- Type
- Rechargeable lithium battery,2000mAh
- Operating time
- Operating time under the normal use and full chargeā„240 mins
- Product size
- 305*162*290mm
- Net Weight
- 4KG
Documents & downloads
Regulatory paperwork & manuals
Pre-cleared documentation for this device. Full tender-pack originals are available on request.
Documents & downloads
Regulatory paperwork & manuals
This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.
Get in touch
Need configuration help, certificates, or volume pricing?
Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork ā usually within one business day.
Related products
See all ā
VET Multiparameter Monitor
VET-E12 VET Multiparameter Monitor

Vet Multiparameter Monitor
VET-2000V Vet Multiparameter Monitor

Vet Multiparameter Monitor
VET-5000V Vet Multiparameter Monitor

Mini Veterinary Monitor
VET-M3T Mini Veterinary Monitor




