vs m100 pulse vacuum horizontal type sterilizer
MoreVET

Pulse Vacuum Horizontal Type Sterilizer

VS-M100 Pulse Vacuum Horizontal Type Sterilizer

SKU
VS-M100
Brand
MoreVET
Manufactured by
MoreVET
Availability
In stock
  • Worldwide shipping
Regulatory: For professional veterinary use only. Certification and regulatory status vary by product and country; confirm local regulatory requirements before purchase or use.

Clinical overview

Built for surgical precision

Feature

-Machine shell: 304 stainless steel , the surface is easy to clean

-Sterilization chamber: Horizontal round chamber made of 304 stainless steel, covered

with external thermal insulation layer.

-Door: Mechanical and electronic double lock, electronic safety interlocks prevent the

opening of the door if the chamber under pressure.

-Trays : two removable grill in a basket for items load

-Built-in electric steam generator. Equipment with water level sensor, when water lack will have a water lack alarm on screen.

-Safety protection against over pressure, over temperature.

-Vacuum pump: water-cooled oil-free vacuum pump, fast vacuum speed, free maintenance.

-Pipe lines: stainless steel pipe lines for water and steam.

-With Printer

 

Technical Specifications

 

PARAMETER

SPECIFICATION

Product form

Vertical

Heating method

Electric heating

Power

15.0KVA

Power

AC380V, 50Hz

Dimensions

(L × W × H): 1150x770x1520mm

Liner size

 (Diameter × Depth): 420 × 700mm

Capacity

100L

Shelves

Two trays

Weight

310kg

Temperature display

 7” LCD Touch screen

Design Pressure

 0.3MPa

Working pressure

-0.8MPa~0.21MPa

Design temperature

150 ℃

Working temperature

121 ℃ / 134 ℃

Number of pulses

0 ~ 99 times

Sterilization time

0 ~ 9999 seconds

Drying time

0 ~ 9999 seconds

Safety valve in sterilization chamber

Open ≧ 0.25Mpa, close ≦ 0.24Mpa

Pulsation amplitude

-80.0KPA~150KPA

Water source of evaporator

softened or purified water, water temperature ≤45 ℃, water pressure 0 ~ 0.05 Mpa

Water source of vacuum pump

Tap water (hardness should not be too high), water pressure 0.10Mpa ~ 0.20Mpa

Air Discharge

> 99 ﹪ (Pulsation times more than 3 times)

Vacuum Drying

Avoid humidifying the disinfection package after disinfection

Pulse exhaust

Positive pressure dynamic pulse exhaust to completely eliminate cold air in the sterilization room and ensure steam saturation

Working procedures

Water injection, preheating, pulse vacuum, sterilization, drying and dormancy are automatically completed

Microcomputer control technology

The sterilizer uses microprocessor intelligent control, man-machine interface, easy to operate, safe and reliable. The parameters and status during operation are displayed dynamically through the digital screen. The equipment works abnormally and automatically detects and alarms after sterilization is completed, the system automatically prompts and is accompanied by a buzzer warning sound

Locking device

Before the start of the sterilization cycle, the interlocking device is not locked after the door is closed, and the door can be closed and opened repeatedly. Only when the door is closed in place, the sterilizer can start to run. During the operation, the sterilizer door should not be opened.

After the start of the cycle operation, if a fault or fault indication occurs, the sterilization chamber is not completely released, and when the interlock device should be locked, the sterilizer door should not be opened

Pulsation mode

Microcomputer control automatically selects the number of pulsations according to the site conditions to ensure the coordination of temperature and pressure

Vacuum mode

Three pre-vacuums to ensure faster heating and more complete sterilization

Safety valve

When the pressure of the sterilizer reaches 240kPa ± 5kPa, the safety valve will automatically open to relieve the pressure

Over pressure protection program

When the pressure in the sterilization chamber reaches 220± 5kPakPa, there is a prompt sound and the pressure can be automatically released

Air Leakage

When the sterilizer is tested in various stages, the pressure increase rate should not be greater than 0.13kPa / min

Dynamic pressure in sterilization chamber

The pressure change in any 2s interval during the sterilizer cycle should not exceed 1000kPa / min

Vacuum pump

The water ring vacuum pump is used, which is simple and convenient, the vacuum rate is fast, and the service life is long. Ensure that the vacuum can reach -80kpa

Pressure Sensor

The built-in pressure sensor automatically detects the pressure in the cavity to ensure the accuracy and efficiency of the pressure in the cavity

Temperature Sensor

The built-in temperature sensor automatically detects the temperature in the cavity to ensure that the cavity is kept within an accurate range of ± 3 ℃ of the operating temperature

Sterilization Mode

Sterilization mode for solid equipment, dressing packaging, rubber products, BD test, high pressure, etc

Automatic drying

Powerful vacuum drying, suitable for different items drying needs; the remaining humidity of the equipment is <0.2%

Seal structure

The sealing ring is made of silicone, and the designed service life is 2 years (1200 times) without aging and deformation

Foot wheel

Yes

Alarm system

High and low temperature alarm system

 

Technical specifications

Engineering at a glance

Documentation, IFU and DOCs available on request — contact our sales team for the full regulatory file.

Product form
Vertical
Heating method
Electric heating
Power
15.0KVA
Power
AC380V, 50Hz
Dimensions
(L × W × H): 1150x770x1520mm
Liner size
(Diameter × Depth): 420 × 700mm
Capacity
100L
Shelves
Two trays
Weight
310kg
Temperature display
7” LCD Touch screen
Design Pressure
0.3MPa
Working pressure
-0.8MPa~0.21MPa
Design temperature
150 ℃
Working temperature
121 ℃ / 134 ℃
Number of pulses
0 ~ 99 times
Sterilization time
0 ~ 9999 seconds
Drying time
0 ~ 9999 seconds
Safety valve in sterilization chamber
Open ≧ 0.25Mpa, close ≦ 0.24Mpa
Pulsation amplitude
-80.0KPA~150KPA
Water source of evaporator
softened or purified water, water temperature ≤45 ℃, water pressure 0 ~ 0.05 Mpa
Water source of vacuum pump
Tap water (hardness should not be too high), water pressure 0.10Mpa ~ 0.20Mpa
Air Discharge
> 99 ﹪ (Pulsation times more than 3 times)
Vacuum Drying
Avoid humidifying the disinfection package after disinfection
Pulse exhaust
Positive pressure dynamic pulse exhaust to completely eliminate cold air in the sterilization room and ensure steam saturation
Working procedures
Water injection, preheating, pulse vacuum, sterilization, drying and dormancy are automatically completed
Microcomputer control technology
The sterilizer uses microprocessor intelligent control, man-machine interface, easy to operate, safe and reliable. The parameters and status during operation are displayed dynamically through the digital screen. The equipment works abnormally and automatically detects and alarms after sterilization is completed, the system automatically prompts and is accompanied by a buzzer warning sound
Locking device
Before the start of the sterilization cycle, the interlocking device is not locked after the door is closed, and the door can be closed and opened repeatedly. Only when the door is closed in place, the sterilizer can start to run. During the operation, the sterilizer door should not be opened. After the start of the cycle operation, if a fault or fault indication occurs, the sterilization chamber is not completely released, and when the interlock device should be locked, the sterilizer door should not be opened
Pulsation mode
Microcomputer control automatically selects the number of pulsations according to the site conditions to ensure the coordination of temperature and pressure
Vacuum mode
Three pre-vacuums to ensure faster heating and more complete sterilization
Safety valve
When the pressure of the sterilizer reaches 240kPa ± 5kPa, the safety valve will automatically open to relieve the pressure
Over pressure protection program
When the pressure in the sterilization chamber reaches 220± 5kPakPa, there is a prompt sound and the pressure can be automatically released
Air Leakage
When the sterilizer is tested in various stages, the pressure increase rate should not be greater than 0.13kPa / min
Dynamic pressure in sterilization chamber
The pressure change in any 2s interval during the sterilizer cycle should not exceed 1000kPa / min
Vacuum pump
The water ring vacuum pump is used, which is simple and convenient, the vacuum rate is fast, and the service life is long. Ensure that the vacuum can reach -80kpa
Pressure Sensor
The built-in pressure sensor automatically detects the pressure in the cavity to ensure the accuracy and efficiency of the pressure in the cavity
Temperature Sensor
The built-in temperature sensor automatically detects the temperature in the cavity to ensure that the cavity is kept within an accurate range of ± 3 ℃ of the operating temperature
Sterilization Mode
Sterilization mode for solid equipment, dressing packaging, rubber products, BD test, high pressure, etc
Automatic drying
Powerful vacuum drying, suitable for different items drying needs; the remaining humidity of the equipment is <0.2%
Seal structure
The sealing ring is made of silicone, and the designed service life is 2 years (1200 times) without aging and deformation
Foot wheel
Yes
Alarm system
High and low temperature alarm system

Documents & downloads

Regulatory paperwork & manuals

Pre-cleared documentation for this device. Full tender-pack originals are available on request.

Documents & downloads

Regulatory paperwork & manuals

This device's IFU, CE Declaration of Conformity, ISO 13485 certificate and (where applicable) FDA 510(k) clearance ship with the order. Reach out below for the pack ahead of purchase.

Get in touch

Need configuration help, certificates, or volume pricing?

Our clinical sales team will scope quantities, voltage, accessories and regulatory paperwork — usually within one business day.